HS 85042100 · ELECTRICAL TRANSFORMERS · Rules of Origin & preferential rate

Data last updated: · MFN duty & IGST verified against ICEGATE (Indian Customs EDI). Rules of Origin per CEPA Annex 3B. Verify your exact HS line before filing.

CEPA eligible
Yes
Value addition (RVC)
40%
Tariff-classification change
CTH Annex 3B rule set at chapter level — it covers the whole chapter, not this code alone
MFN → CEPA basic duty
10% → 0%

Rule of Origin (CEPA Annex 3B, primary source): CTH + VA 40% (CEPA Annex 3B Product-Specific Rule; tariff-shift AND value addition both required).

Qualifying under the Rules of Origin

To claim the CEPA preference on liquid-dielectric power transformers (capacity up to 650 kva) (HS 85042100), the goods must qualify as UAE-originating. The Product-Specific Rule (Annex 3B) is "CTH + VA 40% (CEPA Annex 3B Product-Specific Rule; tariff-shift AND value addition both required)": the goods must undergo a change of tariff heading (CTH) AND add at least 40% regional value content — both conditions, not either/or. Read that rule for what it is: Annex 3B supplies it at chapter level, so it governs hundreds of eight-digit codes rather than this one. It is the correct rule to apply, and it is also the place to check for a more specific carve-out before committing to a claim. Distribution transformers underpin grid and industrial electrification, and India's transmission build-out sustains steady imports. CEPA removes the basic duty, a meaningful cut on heavy, high-value equipment. Transformers are copper- and core-steel-intensive, so the 40% regional-value-content rule turns on where those materials are worked — a UAE winding operation using imported core steel may still fall short, because the core and windings together are most of the cost. BIS applies under both the quality-control order and the Compulsory Registration Order, binding the overseas manufacturer, and grid-connected equipment additionally faces technical compliance requirements from the utility that are independent of the tariff. Verify the origin calculation and the standards route together before committing to the CEPA rate, since the second can outlast the first. A valid Certificate of Origin filed through the eCoO 2.0 system must accompany the shipment; without it, customs charges the 10% MFN rate instead of the preference.

Check your own figures in the Rules of Origin (RVC) qualifier. Qualifying is only half of it — the preference is claimed with a Certificate of Origin, issued in the UAE before shipment or retrospectively within 12 months.

Frequently asked questions

Does liquid-dielectric power transformers (capacity up to 650 kva) qualify for India–UAE CEPA?
Yes, if it meets the Annex 3B Product-Specific Rule "CTH + VA 40% (CEPA Annex 3B Product-Specific Rule; tariff-shift AND value addition both required).": it must BOTH change tariff classification (CTH) AND add at least 40% regional value content — both conditions are required, not either/or.
What is the Rule of Origin for liquid-dielectric power transformers (capacity up to 650 kva)?
Per CEPA Annex 3B: CTH + VA 40% (CEPA Annex 3B Product-Specific Rule; tariff-shift AND value addition both required).. RVC% = [(FOB − value of non-originating materials) / FOB] × 100 (FOB basis).
What proof is needed at import?
A preferential Certificate of Origin filed through eCoO 2.0, presented at customs before clearance. Without it, the 10% MFN duty applies.